: : Page 1 of 5
) ot
| SAFETY DATA SHEET
co
. o.+ & Date Issued : 10/24/2017
He SDS No: F-115 REV 1 PART A
&
@ Date Revised : 12/08/2020
ENTERPRISES Revision No : 1
F-115 REV 1 PART A
1, PRODUCT AND COMPANY IDENTIFICATION 6:
PRODUCT NAME: F-115 REV 1 PART A
GENERAL USE: Polyurethane resin
MANUFACTURER 24 HR. EMERGENCY TELEPHONE NUMBERS
BJB Enterprises, Inc, CHEMTREC (USA & Canada): (800) 424-9300
14791 Franklin Avenue or (703) 527-3887 CCN# 2820
Tustin, CA 92780
Emergency Phone: (714) 734-8450
2. HAZARDS IDENTIFICATION
GHS CLASSIFICATIONS
This product does not meet the criteria for classification.
GHS LABEL
Not Applicable
3. COMPOSITION / INFORMATION ON INGREDIENTS
[etemical Name ee cas
Polyurethane prepolymer :
1,2-Cyclohexanedicarboxylic acid, 1,2-dinonyl ester, branched and linear 474919-59-0
Toluene diisocyanate 26471-62-5
4, FIRST AID MEASURES :
EYES: Immediately flush with plenty of water, After initial flushing, remove any contact lenses and continue flushing for at least 15 minutes. Get
medical advice/attention if irritation develops.
SKIN: Immediately wash skin with soap and plenty of water. Remove contaminated clothin, ‘g. Get medical advice/attention if irritation or rash
develops, Wash clothing before reuse.
INGESTION: If swallowed, call a physician immediately. Do not induce vomiting unless directed to do so by medical personnel. Provided the
patient is conscious, wash out mouth with water. Never give anything by mouth to an unconscious person,
INHALATION: Remove to fresh air. Seek medical advice/attention if breathing becomes difficult or if respiratory irritation develops.
NOTES TO PHYSICIAN: Symptomatic and supportive therapy as needed. Following severe exposure medical follow-up should be monitored
for at least 48 hours,
5. FIRE FIGHTING MEASURES
EXTINGUISHING MEDIA: Water spray, carbon dioxide, dry chemical, or foam,
HAZARDOUS COMBUSTION PRODUCTS: Carbon monoxide, carbon dioxide, nitrogen oxides, and hydrogen cyanide.
FIRE FIGHTING PROCEDURES: Cool fire exposed containers with water spray. Remove containers from the fire area if possible. Donot *
release runoff from fire control methods to sewers or waterways.
FIRE FIGHTING EQUIPMENT: Firefighters should wear positive pressure self-contained breathing apparatus (SCBA) and consider use of
unmanned hose holders or monitor nozzles for fighting large fires.
6. ACCIDENTAL RELEASE MEASURES
SPILL AND LEAK PROCEDURES: Evacuate the area, Clean-up should only be performed by trained personnel. People dealing with a major